.. highlight:: ini
|
|
|
|
===========================
|
|
Basic, aka. "Starter Kit"
|
|
===========================
|
|
|
|
The purpose of this section is to provide you with a *simple*
|
|
configuration which should be more or less guaranteed to work out of
|
|
the box.
|
|
|
|
It is suggested that you use this as-is when first installing, in
|
|
order to rule out any "esoteric" issues that can arise from more
|
|
complicated setups. Once you have this working you can further
|
|
complicate as needed.
|
|
|
|
|
|
Config Folder
|
|
-------------
|
|
|
|
First things first, we need a place for config to live. As mentioned
|
|
in :doc:`overview` the filemon will only look in one place, so we must
|
|
create this folder: ``C:\ProgramData\rattail``
|
|
|
|
Note that ``C:\ProgramData`` is a hidden folder, so you may need to
|
|
tweak options in Windows Explorer to see it.
|
|
|
|
Note that the ``rattail`` user (or whoever the service runs as; see
|
|
:doc:`/base/install/windows/user`) will definitely need "read" access
|
|
to the folder you just created. It probably has it by default but is
|
|
worth a double-check.
|
|
|
|
|
|
Log Folder
|
|
----------
|
|
|
|
Once we get the filemon running, we should expect it to write a log
|
|
file. So create the folder for that: ``C:\ProgramData\rattail\log``
|
|
|
|
Note that the ``rattail`` user will need read *and* write access to
|
|
that folder; you may need to grant the latter.
|
|
|
|
|
|
Testing Folders
|
|
---------------
|
|
|
|
Before we add our config files let's setup some folders which we will
|
|
(eventually) test actual filemon behavior with.
|
|
|
|
The basic config will tell filemon to do the following:
|
|
|
|
* watch ``C:\rattail-test\incoming`` for new files
|
|
* when they appear, move them to ``C:\rattail-test\incoming\processed``
|
|
|
|
So create the folders:
|
|
|
|
* ``C:\rattail-test\incoming``
|
|
* ``C:\rattail-test\incoming\processed``
|
|
|
|
And make sure the ``rattail`` user has read *and* write access to
|
|
them.
|
|
|
|
|
|
Config File: ``rattail.conf``
|
|
-----------------------------
|
|
|
|
This is the "machine-wide" config file (see
|
|
:ref:`machine-wide-config`). It should contain any "global" things
|
|
which might be useful for any Rattail app running on the machine.
|
|
(Even though in practice you probably only use the filemon app.)
|
|
|
|
Note that in production it is suggested to use a "site-wide" config
|
|
file which contains most of the global things, so they can be kept in
|
|
just one place (see :doc:`variations`). But for now we will ignore
|
|
that and just make our ``rattail.conf`` "complete" on its own.
|
|
|
|
So, create the file ``C:\ProgramData\rattail\rattail.conf`` and in it
|
|
put this, perhaps tweaking timezone if desired but ideally leaving
|
|
everything else as-is::
|
|
|
|
############################################################
|
|
#
|
|
# machine-wide rattail config
|
|
#
|
|
############################################################
|
|
|
|
|
|
##############################
|
|
# rattail
|
|
##############################
|
|
|
|
[rattail]
|
|
timezone.default = America/Chicago
|
|
|
|
[rattail.config]
|
|
configure_logging = true
|
|
winsvc.RattailFileMonitor = C:\ProgramData\rattail\filemon.conf
|
|
|
|
|
|
##############################
|
|
# logging
|
|
##############################
|
|
|
|
[loggers]
|
|
keys = root
|
|
|
|
[handlers]
|
|
keys = file, console
|
|
|
|
[formatters]
|
|
keys = generic, console
|
|
|
|
[logger_root]
|
|
handlers = file, console
|
|
level = DEBUG
|
|
|
|
[handler_file]
|
|
class = handlers.RotatingFileHandler
|
|
args = (r'C:\ProgramData\rattail\log\rattail.log', 'a', 1000000, 20, 'utf_8')
|
|
formatter = generic
|
|
|
|
[handler_console]
|
|
class = StreamHandler
|
|
args = (sys.stderr,)
|
|
formatter = console
|
|
|
|
[formatter_generic]
|
|
format = %(asctime)s %(levelname)-5.5s [%(name)s][%(threadName)s] %(funcName)s: %(message)s
|
|
datefmt = %Y-%m-%d %H:%M:%S
|
|
|
|
[formatter_console]
|
|
format = %(levelname)-5.5s [%(name)s][%(threadName)s] %(funcName)s: %(message)s
|
|
|
|
Of course the ``rattail`` user must have read access to this file, so
|
|
you might double-check that.
|
|
|
|
|
|
Config File: ``filemon.conf``
|
|
-----------------------------
|
|
|
|
We will give the filemon service its own config file
|
|
(``filemon.conf``), to avoid cluttering the machine-wide
|
|
``rattail.conf`` file etc.
|
|
|
|
So, create the file ``C:\ProgramData\rattail\filemon.conf`` and in it
|
|
put this::
|
|
|
|
############################################################
|
|
#
|
|
# filemon config
|
|
#
|
|
############################################################
|
|
|
|
|
|
##############################
|
|
# rattail
|
|
##############################
|
|
|
|
[rattail.config]
|
|
include = C:\ProgramData\rattail\rattail.conf
|
|
|
|
[rattail.filemon]
|
|
monitor = incoming
|
|
|
|
incoming.dirs = C:\rattail-test\incoming
|
|
incoming.actions = copy, delete
|
|
incoming.action.copy.func = rattail.files:locking_copy
|
|
incoming.action.copy.args = C:\rattail-test\incoming\processed
|
|
incoming.action.delete.func = os:remove
|
|
|
|
|
|
##############################
|
|
# logging
|
|
##############################
|
|
|
|
[handler_file]
|
|
args = (r'C:\ProgramData\rattail\log\filemon.log', 'a', 1000000, 20, 'utf_8')
|
|
|
|
Again you might make sure the ``rattail`` user has read access to the
|
|
file.
|
|
|
|
|
|
Testing the Setup
|
|
-----------------
|
|
|
|
Once all the above is in place, your basic configuration is complete,
|
|
and you can move on to registering and starting the service; see
|
|
:doc:`/base/install/windows/filemon/register` and
|
|
:doc:`/base/install/windows/filemon/start`.
|
|
|
|
If the service is working properly then you should be able to put a
|
|
file in the ``C:\rattail-test\incoming`` folder, and filemon should
|
|
immediately "move" it to ``C:\rattail-test\incoming\processed``
|
|
(actually it copies the file, then deletes original, though it could
|
|
be configured to truly move instead).
|
|
|
|
The service should log its operations to file, at
|
|
``C:\ProgramData\rattail\log\filemon.log``
|